Description
Fluke F116 116C Multimeter Temperature MicroAmps HVAC Model No.: F116C Brand: FLUKE Built-in thermometer for HVAC applications Microamps to test flame sensors Low input impedance: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas Resistance, continuity, frequency and capacitance Min/Max/Average with elapsed time to record signal fluctuations Compact ergonomic design for one-handed operation Compatible with optional magnetic hanger (ToolPak?) CAT III 600 V safety rated Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Display Digital: 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating Temperature -10 °C to + 50 °C Storage Temperature -40 °C to + 60 °C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery Life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range: 600.0 mV Resolution: 0.1 mV Accuracy: ± ([% of reading] + [counts]): 0.5% + 2 DC volts Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.00 V / 0.1 V Accuracy: ± ([% of reading] + [counts]): 0.5% + 2 Auto volts Range: 600.0 V Resolution: 0.1 V Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) AC millivolts1true-rms Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) AC volts1 true-rms Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.0 V / 0.1 V Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) Continuity Range: 600 Ω Resolution: 1 Ω Accuracy: Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. Ohms Range/Resolution: 600.0 Ω / 0.1 Ω Range/Resolution: 6.000 kΩ / 0.001 kΩ Range/Resolution: 60.00 kΩ / 0.01 kΩ Range/Resolution: 600.0 kΩ / 0.1 kΩ Range/Resolution: 6.000 MΩ / 0.001 MΩ Accuracy: 0.9 % + 1 Range/Resolution: 40.00 MΩ / 0.01 MΩ Accuracy: 1.5 % + 2 Diode Test Range/Resolution: 2.000 V / 0.001 V Accuracy: 0.9% + 2 Capacitance Range/Resolution: 1000 nF / 1 nF Range/Resolution: 10.00 μF / 0.01 μF Range/Resolution: 100.0 μF / 0.1 μF Range/Resolution: 9999 μF / 1 μF Range/Resolution: 100 μF to 1000 μF Accuracy: 1.9% + 2 Range/Resolution: > 1000 μF Accuracy: 5% + 20% LoZ capacitance Range: 1 nF to 500 μF Accuracy: 10% + 2 typical Temperature2(Type-K thermocouple) Range/Resolution: -40 °C to 400 °C / 0.1 °C Accuracy: 1% + 102 Range/Resolution: -40 °F to 752 °F / 0.2 °F Accuracy: 1% + 182 AC μamps true-rms (45 Hz to 500 Hz) Range/Resolution: 600.0 μA / 0.1 μA Accuracy: 1.0% + 2 DC μamps Range/Resolution: 600.0 μA / 0.1 μA Accuracy: 1.0% + 2 Hz (V or A input)2 Range/Resolution: 99.99 Hz / 0.01 Hz Range/Resolution: 999.99 Hz / 0.1 Hz Range/Resolution: 9.999 Hz / 0.001 Hz Range/Resolution: 50.00 Hz / 0.01 Hz Accuracy: 0.1% + 2 Notes: 1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. 2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. 4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F Mechanical & General Specifications Size 167 x 84 x 46 mm (6.57" x 3.31" x 1.82") Weight 550 g Notice: The standard package don't include batteries.Because,the international air shipping forbid to ship liquid,powder and batteries,we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.Thanks for your support!